Touch Probe Cycles: Automatic Datum Setting

15.8 DATUM FROM OUTSIDE OF CORNER (Cycle 414, DIN/ISO: G414)

15

310

TNC 320 | User's Manual Cycle Programming | 5/2013

3rd meas. point 1st axis Q296 (absolute):
Coordinate of the third touch point in the reference
axis of the working plane. Input range -99999.9999
to 99999.9999

3rd meas. point 2nd axis Q297 (absolute):
Coordinate of the third touch point in the minor axis
of the working plane. Input range -99999.9999 to
99999.9999

Spacing in 2nd axis Q327 (incremental): Distance
between third and fourth measuring points in the
minor axis of the working plane. Input range 0 to
99999.9999

Measuring height in the touch probe axis Q261
(absolute): Coordinate of the ball tip center (=
touch point) in the touch probe axis in which
the measurement is to be made. Input range
-99999.9999 to 99999.9999

Set-up clearance Q320 (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to

SET_UP (touch probe table). Input

range 0 to 99999.9999

Clearance height Q260 (absolute): Coordinate in
the touch probe axis at which no collision between
touch probe and workpiece (fixtures) can occur.
Input range -99999.9999 to 99999.9999

Traversing to clearance height Q301: definition
of how the touch probe is to move between the
measuring points:

0

: Move at measuring height between measuring

points

1

: Move at clearance height between measuring

points

Execute basic rotation Q304: Definition of
whether the TNC should compensate workpiece
misalignment with a basic rotation:

0

: Do not execute basic rotation

1

: Execute basic rotation

Datum number in table Q305: Enter the datum
number in the datum or preset table in which the
TNC is to save the coordinates of the corner. If
you enter Q305=0, the TNC automatically sets the
display so that the new datum is on the corner.
Input range 0 to 2999

New datum for reference axis Q331 (absolute):
Coordinate in the reference axis at which the TNC
should set the corner. Default setting = 0 input
range -99999.9999 to 99999.9999

New datum for minor axis Q332 (absolute):
Coordinate in the minor axis at which the TNC
should set the calculated corner. Default setting = 0
input range -99999.9999 to 99999.9999

NC blocks

5 TCH PROBE 414 DATUM INSIDE

CORNER

Q263=+37

;1ST POINT 1ST AXIS

Q264=+7

;1ST POINT 2ND AXIS

Q326=50

;SPACING IN 1ST AXIS

Q296=+95

;3RD POINT 1ST AXIS

Q297=+25

;3RD POINT 2ND AXIS

Q327=45

;SPACING IN 2ND AXIS

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q301=0

;MOVE TO CLEARANCE

Q304=0

;BASIC ROTATION

Q305=7

;NO. IN TABLE

Q331=+0

;DATUM

Q332=+0

;DATUM

Q303=+1

;MEAS. VALUE

TRANSFER

Q381=1

;PROBE IN TS AXIS

Q382=+85

;1ST CO. FOR TS AXIS

Q383=+50

;2ND CO. FOR TS AXIS

Q384=+0

;3RD CO. FOR TS AXIS

Q333=+1

;DATUM