MEASURE INSIDE WIDTH (Cycle 425, DIN/ISO: G425) 16.9

16

TNC 320 | User's Manual Cycle Programming | 5/2013

355

Tool for monitoring Q330: Definition of whether
the TNC is to monitor the tool (See "Tool
monitoring"). Input range 0 to 32767.9, alternatively
tool name with maximum of 16 characters

0

: Monitoring inactive

>0

: Tool number in the tool table TOOL.T

Set-up clearance Q320 (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to

SET_UP (touch probe table), and

is only effective when the datum is probed in the
touch probe axis. Input range 0 to 99999.9999

Traversing to clearance height Q301: definition
of how the touch probe is to move between the
measuring points:

0

: Move at measuring height between measuring

points

1

: Move at clearance height between measuring

points