MEASURE COORDINATE (Cycle 427, DIN/ISO: G427) 16.11

16

TNC 320 | User's Manual Cycle Programming | 5/2013

359

Measuring axis (1..3: 1=principal axis) Q272: Axis
in which the measurement is to be made:

1

: Principal axis = measuring axis

2

: Secondary axis = measuring axis

3

: Touch probe axis = measuring axis

Traverse direction 1 Q267: Direction in which the
probe is to approach the workpiece:

-1

: Negative Traverse direction

+1

: Positive traverse direction

Clearance height Q260 (absolute): Coordinate in
the touch probe axis at which no collision between
touch probe and workpiece (fixtures) can occur.
Input range -99999.9999 to 99999.9999

Measuring log Q281: Define whether the TNC
should create a measuring log:

0

: Do not create a measuring log

1

: Create a measuring log: The TNC saves the

log

file TCHPR427.TXT

as standard in the directory

TNC:\.

2

: Interrupt program run and output measuring log

to the TNC screen. Resume program run with NC
Start.

Maximum limit of size Q288: Maximum
permissible measured value. Input range 0 to
99999.9999

Minimum limit of size Q289: Minimum permissible
measured value. Input range 0 to 99999.9999

PGM stop if tolerance error Q309: Definition of
whether in the event of a violation of tolerance
limits the TNC is to interrupt program run and output
an error message:

0

: Do not interrupt program run, do not output an

error message

1

: Interrupt program run and output an error

message

Tool for monitoring Q330: Definition of whether
the TNC is to monitor the tool (See "Tool
monitoring", page 334
). Input range 0 to 32767.9,
alternatively tool name with maximum of 16
characters

0

: Monitoring inactive

>0

: Tool number in the tool table TOOL.T

NC blocks

5 TCH PROBE 427 MEASURE

COORDINATE

Q263=+35

;1ST POINT 1ST AXIS

Q264=+45

;1ST POINT 2ND AXIS

Q261=+5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q272=3

;MEASURING AXIS

Q267=-1

;TRAVERSE DIRECTION

Q260=+20

;CLEARANCE HEIGHT

Q281=1

;MEASURING LOG

Q288=5.1

;MAXIMUM DIMENSION

Q289=4.95

;MINIMUM DIMENSION

Q309=0

;PGM STOP IF ERROR

Q330=0

;TOOL