beautypg.com

HEIDENHAIN TNC 320 (34055x-06) Cycle programming User Manual

Page 357

background image

MEASURE RIDGE WIDTH (Cycle 426, DIN/ISO: G426) 16.10

16

TNC 320 | User's Manual Cycle Programming | 5/2013

357

2nd meas. point 2nd axis Q266 (absolute):
Coordinate of the second touch point in the minor
axis of the working plane. Input range -99999.9999
to 99999.9999

Measuring axis Q272: Axis in the working plane in
which the measurement is to be made:

1

: Principal axis = measuring axis

2

: Secondary axis = measuring axis

Measuring height in the touch probe axis Q261
(absolute): Coordinate of the ball tip center (=
touch point) in the touch probe axis in which
the measurement is to be made. Input range
-99999.9999 to 99999.9999

Set-up clearance Q320 (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to

SET_UP (touch probe table). Input

range 0 to 99999.9999

Clearance height Q260 (absolute): Coordinate in
the touch probe axis at which no collision between
touch probe and workpiece (fixtures) can occur.
Input range -99999.9999 to 99999.9999

Nominal length Q311: Nominal value of the length
to be measured. Input range 0 to 99999.9999

Maximum dimension Q288: Maximum permissible
length. Input range 0 to 99999.9999

Minimum dimension Q289: Minimum permissible
length. Input range 0 to 99999.9999

Measuring log Q281: Define whether the TNC
should create a measuring log:

0

: Do not create a measuring log

1

: Create a measuring log: The TNC saves the

log

file TCHPR426.TXT

as standard in the directory

TNC:\.

2

: Interrupt program run and output measuring log

to the TNC screen. Resume program run with NC
Start.

PGM stop if tolerance error Q309: Definition of
whether in the event of a violation of tolerance
limits the TNC is to interrupt program run and output
an error message:

0

: Do not interrupt program run, do not output an

error message

1

: Interrupt program run and output an error

message

Tool for monitoring Q330: Definition of whether
the TNC is to monitor the tool (See "Tool
monitoring", page 334
). Input range 0 to 32767.9,
alternatively tool name with maximum of 16
characters

0

: Monitoring inactive

>0

: Tool number in the tool table TOOL.T

NC blocks

5 TCH PROBE 426 MEASURE RIDGE

WIDTH

Q263=+50

;1ST POINT 1ST AXIS

Q264=+25

;1ST POINT 2ND AXIS

Q265=+50

;2ND POINT 1ST AXIS

Q266=+85

;2ND POINT 2ND AXIS

Q272=2

;MEASURING AXIS

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q311=45

;NOMINAL LENGTH

Q288=45

;MAXIMUM DIMENSION

Q289=44.95

;MINIMUM DIMENSION

Q281=1

;MEASURING LOG

Q309=0

;PGM STOP IF ERROR

Q330=0

;TOOL