beautypg.com

1 fundamentals, Overview, Fundamentals – HEIDENHAIN TNC 320 (34055x-06) Cycle programming User Manual

Page 282

background image

Touch Probe Cycles: Automatic Datum Setting

15.1 Fundamentals

15

282

TNC 320 | User's Manual Cycle Programming | 5/2013

15.1

Fundamentals

Overview

When running touch probe cycles, Cycle 8 MIRROR
IMAGE, Cycle 11 SCALING and Cycle 26 AXIS-
SPECIFIC SCALING must not be active.

HEIDENHAIN only gives warranty for the function of
the probing cycles if HEIDENHAIN touch probes are
used.

The TNC must be specially prepared by the machine
tool builder for the use of a 3-D touch probe.

Refer to your machine manual.

The TNC offers twelve cycles for automatically finding reference
points and handling them as follows:

Setting the determined values directly as display values

Entering the determined values in the preset table

Entering the determined values in a datum table