beautypg.com

HEIDENHAIN TNC 320 (34055x-06) Cycle programming User Manual

Page 339

background image

MEASURE ANGLE (Cycle 420, DIN/ISO: G420) 16.4

16

TNC 320 | User's Manual Cycle Programming | 5/2013

339

2nd meas. point 2nd axis Q266 (absolute):
Coordinate of the second touch point in the minor
axis of the working plane. Input range -99999.9999
to 99999.9999

Measuring axis Q272: Axis in which the
measurement is to be made:

1

: Principal axis = measuring axis

2

: Secondary axis = measuring axis

3

: Touch probe axis = measuring axis

Traverse direction 1 Q267: Direction in which the
probe is to approach the workpiece:

-1

: Negative Traverse direction

+1

: Positive traverse direction

Measuring height in the touch probe axis Q261
(absolute): Coordinate of the ball tip center (=
touch point) in the touch probe axis in which
the measurement is to be made. Input range
-99999.9999 to 99999.9999

Set-up clearance Q320 (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to

SET_UP (touch probe table). Input

range 0 to 99999.9999

Clearance height Q260 (absolute): Coordinate in
the touch probe axis at which no collision between
touch probe and workpiece (fixtures) can occur.
Input range -99999.9999 to 99999.9999

Traversing to clearance height Q301: definition
of how the touch probe is to move between the
measuring points:

0

: Move at measuring height between measuring

points

1

: Move at clearance height between measuring

points

Measuring log Q281: Define whether the TNC
should create a measuring log:

0

: Do not create a measuring log

1

: Create a measuring log: The TNC saves the

log

file TCHPR420.TXT

as standard in the directory

TNC:\.

2

: Interrupt program run and output measuring log

to the TNC screen. Resume program run with NC
Start.

NC blocks

5 TCH PROBE 420 MEASURE ANGLE

Q263=+10

;1ST POINT 1ST AXIS

Q264=+10

;1ST POINT 2ND AXIS

Q265=+15

;2ND POINT 1ST AXIS

Q266=+95

;2ND POINT 2ND AXIS

Q272=1

;MEASURING AXIS

Q267=-1

;TRAVERSE DIRECTION

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+10

;CLEARANCE HEIGHT

Q301=1

;MOVE TO CLEARANCE

Q281=1

;MEASURING LOG