Using Touch Probe Cycles

13.2 Before You Start Working with Touch Probe Cycles

13

258

TNC 320 | User's Manual Cycle Programming | 5/2013

Touch trigger probe, probing feed rate: F in touch
probe table

In

F you define the feed rate at which the TNC is to probe the

workpiece.

Touch trigger probe, rapid traverse for positioning:
FMAX

In

FMAX you define the feed rate at which the TNC pre-positions

the touch probe, or positions it between measuring points.

Touch trigger probe, rapid traverse for positioning:
F_PREPOS in touch probe table

In

F_PREPOS you define whether the TNC is to position the touch

probe at the feed rate defined in FMAX or at rapid traverse.

Input value =

FMAX_PROBE: Position at feed rate from FMAX

Input value =

FMAX_MACHINE: Pre-position at rapid traverse

Multiple measurements

To increase measuring certainty, the TNC can run each probing
process up to three times in sequence. Define the number
of measurements in machine parameter

ProbeSettings >

Configuration of probe behavior > Automatic mode: Multiple

measurements with probe function. If the measured position
values differ too greatly, the TNC outputs an error message
(the limit value is defined in

Confidence interval of multiple

measurements). With multiple measurement it is possible to
detect random errors, e.g. from contamination.

If the measured values lie within the confidence interval, the TNC
saves the mean value of the measured positions.

Confidence interval of multiple measurements

When you perform a multiple measurement, you store the
value that the measured values may vary in

ProbeSettings >

Configuration of probe behavior > Automatic mode: Confidence

interval of multiple measurements. If the difference in the
measured values exceeds the value defined by you, the TNC
outputs an error message.