6 tnc error messages -21, Tnc error messages during programming -21, 6 tnc error messages – HEIDENHAIN TNC 360 User Manual User Manual
Page 231
12-21
TNC 360
12
Tables, Overviews, Diagrams
12.6 TNC Error Messages
The TNC automatically generates error messages when it detects such
things as
• Incorrect data input
• Logical errors in the program
• Contour elements that are impossible to machine
• Incorrect use of the touch probe system
An error message containing a program block number was caused by an
error in that block or in the preceding block. To clear a TNC error message,
first correct the problem and then press the CE key.
Some of the more frequent TNC error messages are explained in the
following list.
TNC error messages during programming
ENTRY VALUE INCORRECT
• Enter a correct LBL number.
• Observe the input limits.
EXT. IN-/OUTPUT NOT READY
The external device is not correctly connected.
FURTHER PROGRAM ENTRY IMPOSSIBLE
Erase some old files to make room for new ones.
LABEL NUMBER ALLOCATED
Label numbers can only be assigned once.
JUMP TO LABEL 0 NOT PERMITTED
Do not program CALL LBL 0.