12.1 General User Parameters

Display step for coordinate axes

MP 7290

Function

Value

• Display step 0.001 mm .................................................................................................................................... 0

• Display step 0.005 mm .................................................................................................................................... 1

Q parameters and status display

MP 7300

Function

Selections

Value

• Q parameters and status display

Do not erase ................................................................................. +0
Erase with M02, M30 and END PGM .......................................... +1

• Last programmed tool after

Do not activate ............................................................................. +0

power interruption

Activate ........................................................................................ +4

Graphics display

Entry range: 0 to 3 (sum of the individual values)

MP 7310

Function

Selections

Value

• View in 3 planes

Projection method 1 .................................................................... +0

according to ISO 6433

Projection method 2 .................................................................... +1

• Rotate coordinate system

Rotate ........................................................................................... +2

by 90° in the working plane

Do not rotate ................................................................................ +0

Parameters for machining and program run

Effect of cycle 11 SCALING

MP 7410

Function

Value

• SCALING effective in 3 axes ............................................................................................................................ 0

• SCALING effective in the working plane ......................................................................................................... 1

MP 7411 Tool compensation data in the TOUCH PROBE block

Function

Value

• Overwrite current tool data with the calibrated data of the touch probe ......................................................... 0

• Retain current tool data .................................................................................................................................... 1