beautypg.com

Digitizing range, Input data, Setting the scanning range – HEIDENHAIN TNC 360 User Manual User Manual

Page 194: 2 digitizing range, Z. . . y x z

background image

9-3

TNC 360

9

Digitizing 3D Surfaces

Fig. 9.1:

Clearance height and digitizing
range

TOUCH
PROBE

Z

.

.

.

Y

X

Z

MAX

MIN

S

Z

5

GOTO

ENT

ENT

e.g.

9.2 Digitizing Range

The digitizing range is defined in cycle 5: RANGE. The model to be
scanned must lie within this range. You also enter the name of the file for
the digitized data as well as a clearance height for pre-positioning the
touch probe.

Input data

• PGM NAME

Name of the file in which the digitized data is to be stored

• MIN POINT RANGE

Coordinates of the lowest point in the range to be digitized

• MAX POINT RANGE

Coordinates of the highest point in the range to be digitized

• CLEARANCE HEIGHT

Position in the probe axis at which the probe cannot collide with the
model

Setting the scanning range

TCH PROBE: 0 REF. PLANE

Select digitizing cycle 5: RANGE.

TCH PROBE: 5 RANGE

Confirm selection.

PGM NAME?

Enter the name of the file in which the digitizing data are to be stored.

TCH PROBE AXIS?

Enter the touch probe axis.