beautypg.com

Line-by-line digitizing, Starting position, Contour approach – HEIDENHAIN TNC 360 User Manual User Manual

Page 196: Input data, 3 line-by-line digitizing, Yx z

background image

9-5

TNC 360

9

Digitizing 3D Surfaces

Fig. 9.2:

Scanning a line on the 3D surface

9.3 Line-By-Line Digitizing

The MEANDER cycle scans and digitizes a 3D
contour in a back-and-forth (“meandering”) series
of parallel lines.

Starting position

• Coordinates from the RANGE cycle:

X and Y coordinates of the MIN point
Z coordinate = CLEARANCE HEIGHT

• Automatically move to the starting position:

first Z, then X and Y

Contour approach

The touch probe moves in the negative Z direction towards the model.
Upon contact, the TNC stores the position.

Input data

• LINE DIRECTION

Coordinate axis in whose positive direction the touch probe moves
(beginning with the first contour point).

• LIMIT IN NORMAL LINES DIRECTION

Distance the probe is retracted from the model after each deflection of
the stylus during scanning

• LINE SPACING

The offset by which the probe moves at the ends of the lines before
scanning the next line

• MAX. PROBE POINT INTERVAL

Maximum spacing between consecutive digitized positions

The LINE SPACING and MAX. PROBE POINT INTERVAL cannot exceed 5 mm.

Y

X

Z