Parameters for 3d touch probes, Parameters for tnc displays and the editor – HEIDENHAIN TNC 360 User Manual User Manual
Page 214

TNC 360
12-4
12
Tables, Overviews, Diagrams
12.1 General User Parameters
Parameters for 3D Touch Probes
Signal transmission type
MP 6010
Function
Value
• Cable transmission ........................................................................................................................................... 0
• Infrared transmission ....................................................................................................................................... 1
Traversing behavior of touch probe
Parameter
Function
Value
MP 6120
Probing feed rate in mm/min ............................................................... 80 to 30 000
MP 6130
Maximum measuring range to first scanning point in mm .................... 0 to 30 000
MP 6140
Safety clearance over probing point
during automatic probing, in mm ........................................................... 0 to 30 000
MP 6150
Rapid traverse for probe cycle in mm/min ........................................... 80 to 30 000
Parameters for TNC Displays and the Editor
Programming station
MP 7210
Function
Value
• TNC with machine ........................................................................................................................................... 0
• TNC as programming station with active PLC ................................................................................................. 1
• TNC as programming station with inactive PLC .............................................................................................. 2