9

Digitizing 3D Surfaces

e.g.

9.3

Line-By-Line Digitizing

.

.

.

0

8

.

MAX. PROBE POINT INTERVAL ?

Enter the maximum probe point interval, for example 0.8 mm.

Resulting NC blocks:

TCH PROBE 6.0

MEANDER

TCH PROBE 6.1

DIRECTN: X

TCH PROBE 6.2

TRAVEL: 0.5 L.SPAC: 0.2
P.P. INT: 0.8

Before cycle 6: MEANDER the program must have a range defined in digitizing cycle 5: RANGE.