59
RAID controller X that was
operating in non-mirrored
caching mode has detected a
non-recoverable memory fault
in the cache memory area.
Reboot the RAID system, then
the Profile. In Open SANs,
consult reboot procedures in the
Open SAN Instruction Manual,
or contact product support.
Replace the RAID controller if
needed.
A hardware failure occurred on
RAID controller X which
caused cache to be disabled.
System bandwidth will be
degraded.
Reboot the RAID system, then
the Profile. In Open SANs,
consult reboot procedures in the
Open SAN Instruction Manual,
or contact product support.
Replace the RAID controller if
needed.
The non-volatile memory on
RAID controller X was found to
be uninitialized. The controller
has initialized it to a default
state, and it will be functional
after a reboot.
Reboot the RAID system, then
the Profile. In Open SANs,
consult reboot procedures in the
Open SAN Instruction Manual,
or contact product support.
Replace the RAID controller if
needed.
RAID controller X is unable to
determine the correct logical
configuration of all units in the
system. Some units may become
unusable.
Reboot the RAID system, then
the Profile. In Open SANs,
consult reboot procedures in the
Open SAN Instruction Manual,
or contact product support.
Replace the RAID controller if
needed.
The redundant controller is no
longer responding to queries
from RAID controller X. The
system may be operation, but
Fibre Channel redundancy is
lost.
Reboot the RAID system, then
the Profile. In Open SANs,
consult reboot procedures in the
Open SAN Instruction Manual,
or contact product support.
Replace the RAID controller if
needed.
Fibre Channel port# 1 on the
Fibre Channel Disk board has
failed.
Restart the Profile, recheck for
messages, then run Profile
system diagnostics if needed.
Fibre Channel port# 2 on the
Fibre Channel Disk board has
failed.
Restart the Profile, recheck for
messages, then run Profile
system diagnostics if needed.
Both Fibre Channel ports on the
Fibre Channel Disk board have
failed.
Restart the Profile, recheck for
messages, then run Profile
system diagnostics if needed.
RAID storage messages
Possible cause
Corrective action