Making settings for a profile xp system – Grass Valley Profile XP Service Manual User Manual
Page 146

Appendix A Diagnostic Tools
146
Profile XP Service Manual
23 July 2004
7. Click
OK
when you are finished configuring the GPI outputs.
8. Restart the system.
You can test the GPI outputs by using the
Test
button.
If you re-install Profile System Software, you must reconfigure the GPI outputs. If
you allocate GPI outputs 7 and 8 for use by some other application, you must restart
the Profile System.
Making settings for a Profile XP system
Select
Device| Device Options
to make the following settings that determine how
NetCentral Lite monitors the media platform. Click the
Apply
button to put the
settings into effect.
Log Repeated Messages —
Adjust the slider to set how frequently NetCentral
will send a repeated message to a log file. Use this feature to prevent log files from
filling up with routine messages.
Resend Messages —
Specify the amount of time for correcting a problem before
an Alarm message is re-sent for that problem.
Thermal Warnings —
Enable by clicking in the check-box, then specify the rate
of temperature increase at which NetCentral sends a Warning message.