Checking NetCentral messages – PFC 500
23 July 2004
Profile XP Service Manual
57
The storage system is at
maximum capacity and is
unable to store additional
media.
Delete any unused media files.
The system has reported
sufficient storage capacity and is
able to store additional media.
RAID controller X cannot
access drive N in chassis Y. The
drive may have failed or is
removed.
Replace the drive module.
RAID controller X detected a
replacement for drive N in
RAID chassis Y, but the drive
does not have adequate capacity
for the controller to start
rebuilding data.
Replace the drive module.
RAID controller X does not
support drive N in chassis Y.
The drive is unusable.
Replace the drive module.
RAID controller X does not
support the firmware on drive N
in chassis Y.
Replace the drive module.
RAID controller X does not
support drive N in chassis Y.
The drive is unusable.
Replace the drive module.
RAID controller X has cleared
media defects reported by drive
N in chassis Y.
Replace the drive module.
RAID controller X has
scheduled a disk block for
reallocation after drive N in
chassis Y reported a media
error.
Replace the drive module.
RAID chassis Y associated with
controller X has resumed
normal operation.
Fan module on RAID chassis Y
associated with controller X was
disabled. The controller(s) will
power down the drives and go
into standby mode if the fans are
not operational within 2
minutes.
Check whether the fan module is
inserted correctly into the
chassis or replace the Fan
module.
RAID storage messages
Possible cause
Corrective action