beautypg.com

Joystick calibration, Touch screen calibration – Grass Valley Kayak HD Installation v.6.8.8 User Manual

Page 84

background image

84

Kayak HD — Installation and Service Manual

Section 2 — Installation

Joystick Calibration

In the Joystick Calibration data pad press the

Start Calibr.

button and follow

the instructions:

1.

Move the joystick to the bottom right corner, twist it to the left stop
position, and press

OK

.

2.

Let the joystick return to the center position and press

OK

.

3.

Move joystick to the top left corner, twist to right stop and press

OK

.

The data pad will indicate that the Status is

adjusted

when done.

Touch Screen Calibration

To open the

Touchscreen Calibration

menu:

1.

From the Kayak HD

Home

menu press

Install

. The

Touchscreen Calibration

data pad displays on the screen.

If the

Touchscreen Calibration

data pad is not displayed at first, touch the

Panel Misc.

button at the bottom of the screen, then touch

Calibr.

You can also use the following shortcut:

Menu Lock + User 3

2.

In the

Touchscreen Calibration

data pad touch the

Start Calibr.

button.

3.

The

Touchscreen Calibration

menu displays a simple set of instructions

explaining how to calibrate the touch screen. You are asked to touch a
red dot in three corners of the menu screen so that the system can
optimize the touch screen display.

Note

If the touch screen is so far out of calibration that you cannot call up the
Touchscreen Calibration data pad using the Menu Lock + User 3 commands,
plug in a USB mouse to one of the two active panel USB connectors (USB
Port2 2 and 4). This allows you to press the correct buttons (using the
mouse) to use the procedure described above in

Touch Screen Calibration

to

call up the Touchscreen Calibration data pad. Once you can see the Touch-
screen Calibration
data pad you should be able to perform the calibration
procedure using your finger or a stylus.