Kayak HD — Installation and Service Manual

Appendix A — Specifications

Table 14. Control Panel Connection

Type of connection

10/100 Base T

Protocol

TCP(UDP)/IP

Cable and connectors

CAT5 UTP, RJ45 connectors;

Max. Cable Length

100m / 300ft

1 Frame and up to 4 Panels connect without use of external hub/switch.

Table 15. Power

4 RU Frame

Line voltage

100V-240V AC +/-10% autorange, power factor corrected. Automatic
line-voltage sensing for 120V and 240V sources.

Line frequency

50/60Hz +/- 5%

Power consumption

max. 400W

Leakage current

< 2.5 mA

DC-OUT for control panel

48V DC, max 3A

8 RU Frame

Line voltage

100V-240V AC +/-10% autorange, power factor corrected. Automatic
line-voltage sensing for 120V and 240V sources.

Line frequency

50/60Hz +/- 5%

Power consumption

max. 800W

Leakage current

< 2.5 mA

DC-OUT for control panel

48V DC, max 3A

Kayak HD 100C Control Panel

DC-IN

48V DC In, max 1.3A

Kayak HD 150C, 200C, 200 Control Panel

DC-IN

48V DC In, max 1.3A

Kayak HD 250C AND 250 Control Panels

DC-IN

48V DC In, max 1.3A

Kayak HD 300 Control Panel

DC-IN

48V DC In, max 1.3A

KDD-PSU Frame (Remote Control Panel Power Supply)

Line voltage

100V-240V AC +/-10%, power factor corrected

Line frequency

50/60Hz +/- 5%

Power consumption

max. 375W

Leakage current

< 2 mA at 250V AC