beautypg.com

Control interfaces, Supported gvg100 commands, Appendix b — control interfaces – Grass Valley Kayak HD Installation v.6.8.8 User Manual

Page 171

background image

Kayak HD — Installation and Service Manual

171

Appendix

B

Control Interfaces

Supported GVG100 Commands

Name

Command Code

Remark

CROSSPOINT BUS COMMAND

C1-C4
41-44

Crosspoint interpretation:

GVG code

Interpretation

00H

BLK

01H...0x08H

INPUT 1...8

09H

COLOR BGD 1

All other codes directly address the internal crosspoint numbers of the
switcher.

ANALOG CONTROL COMMAND

C5

Only Write
supported: [Control# (EX) - ControlName]
[00H (01H) - Transition Lever Arm]
GVG100 max value of 0xFFF is linear translated to the DD transition
maximum of 0x7FFF

PUSHBUTTON COMMAND

C6
(C7)

Only Write
C6 -> on
C7 -> off
Supported are:
Program Bus Crosspoint 0-9 / 00H - 09H / C6
AUTO TANS / 0BH / C6
DSK MIX / 0CH / C6
DSK ON / 0DH / C6,C7
WIPE / 0EH / C6
MIX / 0FH / C6
Preset Bus Crosspoint 0-9 / 10H -19H / C6
REVERSE WIPE / 1DH / C6,C7
FADE TO BLACK / 1FH / C6
Key Bus Crosspoint 0-9 / 20H -29H / C6
GVG100 Wipe Pattern / 30H -39H / C6
BKGD / 48H / C6,C7
KEY / 49H / C6,C7
CUT / 4AH / C6
KEY ON / 52H / C6,C7

WIPE PATTERN SELECT COMMAND

C8

Only Write
GVG100 related wipe numbers are directed to the corresponding wipe pattern
in the DD switcher (00H -> Vertical Wipe, 01H-> Left Corner Wipe,...).
All other pattern codes directly address the internal wipe pattern of the
switcher.

TRANSITION MODE COMMAND

CA

Only Write