Kayak hd frame connectors – Grass Valley Kayak HD Installation v.6.8.8 User Manual
Page 45

Kayak HD — Installation and Service Manual
45
Kayak HD Frame Connectors
Kayak HD Frame Connectors
Table 1. Kayak HD Frame Connectors
Designation
Note
AC POWER IN 1
AC POWER IN 2
Mains connectors (IEC-320, CEE-22) to provide power supply to the
video processor frame.
Operating Voltage: 100V-240V AC +/-10% widerange
Caution: For continued protection against risk of fire, replace only with
same type and rating of fuse. 2x T 6.3A /H 250
Double-pole or neutral fusing — Disconnect mains power prior to servic-
ing. After a fuse opens, high voltage in parts of the equipment may still
present a hazard to you during servicing.
AC POWER SWITCH
Frame power switch.
INPUTS
IN1 – IN24
BNC / Serial Comp (ITU-R 656) video inputs
Maximum cable length 100m HD, 300m SD (typical).
INPUTS
IN25 - IN48
BNC / Serial Comp (ITU-R 656) video inputs
In 25 …48: Maximum cable length 100m HD, 300m SD (typical).
NOTE: The last 4 inputs in each group have the scalar option.
INPUTS
IN49 - IN73
(8 RU FRAME ONLY)
BNC / Serial Comp (ITU-R 656) video inputs
In 49 …73: Maximum cable length 100m HD, 300m SD (typical).
NOTE: The last 4 inputs in each group have the scalar option.
INPUTS
IN74 - IN96
(8 RU FRAME ONLY)
BNC / Serial Comp (ITU-R 656) video inputs
In 74 …96: Maximum cable length 100m HD, 300m SD (typical).
NOTE: The last 4 inputs in each group have the scalar option.
24 MAPPABLE OUTPUTS
BNC / Serial Comp (ITU-R 656)
Double Program output
Preview output
Clean output
Clean Preview output
AUX 1 – AUX10
Auxiliary Outputs, BNC / Serial Comp (ITU-R 656)
SD ANALOG REFERENCE INPUT PAIR
Reference input, BNC / 75 ohms
Loop through sync input for analog Blackburst or CCVS signal.
HD ANALOG REFERENCE INPUT PAIR
Reference input, BNC / 75 ohms
Loop through sync input for analog Blackburst or CCVS signal.
RS 422/485 PORTS
(PORTS 1-8)
Eight control ports, 9-pin D-type female
RS422/485 serial ports for devices such as DVEs, Editors, Routers and for
Machine Control (Disk Servers, VTR).
GPI / GPO / TALLY
INPUTS 1-8, 9-16
OUTPUTS 1-32, 33-64
50-pin D-type female
General-purpose interface connector with 8 input channels and 32 output
channels.
The connector is used for Tally also.
Refer table below for respective pin assignment.
LAN
Four RJ45 connectors for LAN connection to the Control Panel. Optional
cables with lengths of 20m or 50m can be ordered.
DC POWER IN
Input connector for external DC Power Supply Unit (KDD-PSU) for redun-
dancy (High current D-Sub, female). (See KDD-PSU Power Supply Option
.)
Input voltage: 48V/ 5A
Note: The external power supply unit must comply with the SELV (Safety
Extra Low Voltage) standard exclusively. ELV and TNV standard is not per-
mitted.
Additionally the 8V DC voltage for RAM Recorder buffering can be sup-
plied via this socket.
DC POWER OUT
Output connector for Panel DC Power Supply.
(High current D-Sub, male).
Output voltage: 48V/ 1.6A max.
A 10m DC power connecting cable is supplied.