Fan failure, Hd ram recorder field upgrade procedure, Field upgrade parts list – Grass Valley Kayak HD Installation v.6.8.8 User Manual
Page 156: Installing hd ram recorder upgrade

156
Kayak HD — Installation and Service Manual
Section 4 — Maintenance
Fan Failure
CAUTION If a fan fails to operate it should be replaced immediately. The Kayak HD frame
shuts down when its internal temperature reaches 75-degrees C.
If there is a fan failure, the network panel displays an exclamation mark (
!
).
The fan board is hot pluggable (as are the power supplies and M/E boards).
CAUTION Do not attempt to run the Kayak HD system without functioning fans. This
can cause sever damage to circuit boards.
HD RAM Recorder Field Upgrade Procedure
In addition to the 6.8.8 software, for a field upgrade of HD RAM Recorder
on the Kayak HD, a new controller board (with DIMMs) and a software
license must be installed.
Field Upgrade Parts List
To upgrade from an earlier version of software/hardware to install HD
RAM Recorder, the following are required:
•
New
6910000xx
Controller Board.
•
USB Memory Stick with the HD RAM Recorder license and current
software
•
One or Two 4GB DIMMS
•
One 4GB DIMM for HD RAM Recorder
•
One 4GB DIMM for KlipCache (optional)
•
These release notes
Installing HD RAM Recorder Upgrade
CAUTION Use antistatic procedures to prevent electrical damage to sensitive electronic
components.
To install the HD RAM Recorder upgrade on the Kayak HD, complete the
following steps.
1.
Back up all current applications and environmental data from the
existing controller board to a USB stick or Sidepanel hard drive.
2.
Install 6.8.8 or later software to the control panel and Sidepanel, and
verify the installation.
3.
Install the RAMREC license from the USB memory stick provided.