65 a shielded cutting (stainless steel), 65 a shielded cutting (stainless steel) -27, Powermax – Hypertherm Powermax105 Service Manual User Manual
Page 99

Machine Torch SeTup
powermax
105 Service Manual
6-27
65 A Shielded cutting (Stainless Steel)
Air flow rate – slpm/scfh
Hot
175 / 370
Cold
209 / 443
Metric
Material
thickness
torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay time
best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
Voltage
mm
mm
mm
%
seconds
(mm/min)
Volts
(mm/min)
Volts
2
1.5
3.8
250
0.1
8100
125
10000
121
3
0.2
6700
125
8260
123
4
0.5
5200
125
6150
124
6
2450
126
2850
126
8
0.7
1500
129
1860
129
10
4.5
300
960
132
1250
132
12
1.2
750
135
920
134
16
Edge Start
500
139
500
139
20
300
143
370
143
English
Material
thickness
torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay time
best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
Voltage
inches
inches
inches
%
seconds
ipm
Volts
ipm
Volts
16GA
0.06
0.15
250
0.1
345
124
426
121
10GA
240
125
296
123
3/16
0.2
155
126
168
125
1/4
0.5
80
126
96
126
3/8
0.7
40
131
52
131
1/2
0.18
300
1.2
26
136
32
135
5/8
Edge Start
20
139
20
139
3/4
14
142
15
142