Fault codes, Displaying the service screen, Fault codes -23 – Hypertherm Powermax105 Service Manual User Manual
Page 161: Displaying the service screen -23, Powermax

TroubleshooTing and sysTem TesTs
powermax
105 Service Manual
8-23
Fault codes
Fault codes displayed on the LCD screen in “service mode” are in the format N-nn-n. Fault codes displayed on the LCD
screen in “operator mode” have one fewer digit and appear in the format N-nn. The tables in this section show all digits.
The fault priority is assigned based on the fault code value: the higher the number, the higher the fault priority. Only one
fault code is set at one time. If more than one fault occurs at the same time, only the fault with the highest priority is set.
Displaying the service screen
For troubleshooting faults, display the service screen by simultaneously pressing the automatic/manual and current/gas
mode selectors for approximately two (2) seconds. The service screen displays.
Designator
Description
I
Current set/read
C
LCD contrast
B
LCD brightness (per cent)
P
Pressure set/read
G
Gas test enable (1)/disable (0)
IP
Boost circuit current (not present on 400 V CE)
VL
Incoming AC line voltage
TI
Inverter module temperature (°C)
TP
Boost module temperature (°C), not present on 400 V CE
VB
DC buss voltage
AH
Arc hours
F
Live fault code
T
Torch identifier (amps/H hand or M machine/lead length in feet)
S
DSP/Control board software versions
1 - 6
1 is the most recent fault code; 6 is the oldest fault code
1
2
3
4
5
6
Note: Fault codes beginning with zero (0-nn-n) are not recorded in the fault log.