10. Remove the three front end panel mounting screws.
11. Remove the front end panel from the power supply.
12. Align the new front end panel with the power supply and tighten the three supplied mounting screws to
23 kg cm (20 in.-lbs).
13. Insert the threaded end of the work lead receptacle in the front end panel, making sure that the keyway is facing up.
14. Place the washer over the work lead receptacle and tighten the nut onto the work lead receptacle.
15. Secure the work cable to the work lead receptacle by tightening the bolt.
16. Secure the quick disconnect to the front end panel by tightening the four mounting screws to 23 kg cm (20 in.-lbs).
Front end panel
mounting screws
Keyway up
Work lead receptacle