Power SuPPly ComPonent rePlaCement
powermax
105 Service Manual
9-27
Connect the machine interface cable
1. Remove the machine interface receptacle’s cover from the rear of the power supply.
Note: The cover on the machine interface receptacle prevents dust and moisture from damaging the receptacle
when not in use. This cover (part number 127204) should be replaced if damaged or lost.
2. Connect the machine interface cable CPC to the power supply.
3. Terminate the machine interface cable spade terminals inside the electrical enclosure of listed and certified torch
height controllers or CNC controllers to prevent unauthorized access to the connections after installation. Verify that
the connections are correct and that all live parts are enclosed and protected before operating the equipment.
Note: The integration of Hypertherm equipment and customer-supplied equipment including interconnecting
cords and cables, if not listed and certified as a system, is subject to inspection by local authorities at the
final installation site.
See the "Mechanized Cutting" section for more information on each type of signal available through the
machine interface cable.
CPC
Spade terminals