Test 1 – Voltage input
Symptom: Voltage fault (0-60-0, -1 or -2)
• Check the line voltage at the top of the power switch (S1) with the switch in the OFF position.
• Check the input voltage to the input diode bridge with the switch in the ON position.
- The AC voltage between any 2 input wires should equal the line voltage.
• If there is proper voltage to the power switch and low voltage to the input diode bridge, replace the power
switch.
• Check the output voltage of the input diode bridge.
- Output VDC = Line Voltage x 1.414 VDC.
Note: All values are ±15%.
Three phase
L1
Black (CSA)
Brown (CE)
L2
White (CSA)
Black (CE)
L3
Red (CSA)
Gray (CE)
PE
Green (CSA)
Green/Yellow (CE)
• If there is a fault and the diode bridge output value is correct:
- Display the service screen and confirm that the value “VL” is ±15% of AC line voltage.
• If there is a fault and the “VL” value is correct:
- Verify the DSP board by replacing it with a known good board.
- If DSP board is not the problem, replace the power board and the PFC IGBT module (CSA and 230-400 V
CE units only).
LV
3 inputs to GRD
LV/1.732
Ground (GRD)
Black wire
LV
LV
LV X
1.414
LV = incoming line voltage