Fault codes and solutions, Fault codes and solutions -25, Powermax – Hypertherm Powermax105 Service Manual User Manual
Page 163

TroubleshooTing and sysTem TesTs
powermax
105 Service Manual
8-25
0-nn-n
These fault codes identify operational faults. On the operator screen, the last digit is omitted. Display the service screen
for more information on faults 11, 19, 30, 40, 60, and 99.
Fault
code
Description
Power
lED
Fault
lED
Fault
icon
Solutions
0-11-0 Remote controller cut mode
invalid
On
Off
There is a problem with the remote controller
or the software interface to the system. The
system cannot interpret the cut mode, cut
current, or pressure information coming from
the controller.
• Fix the controller.
• Check the interface cable.
0-11-1 Remote controller current
invalid
0-11-2 Remote controller pressure
invalid
0-12-1 Output gas pressure low
On
Off
• Adjust the gas inlet pressure as needed.
• Check for kinked or blocked air lines.
• Perform Test 10.
0-12-2 Output gas pressure high
• The gas subsystem is not working properly.
Check the valve.
• Perform Test 10.
0-12-3 Output gas pressure unstable
Fault codes and solutions
Each table below describes a fault category and suggests solutions for each fault code. Several of the fault solutions
show a test number. Refer to page 8-42 System tests to perform the indicated numbered test.
Note: If a fault occurs while using a generator, turning the power switch quickly to OFF and then to ON again
(sometimes called a “quick reset”) may not clear the fault. Instead, turn OFF the power supply and wait 30 to
45 seconds before turning ON again.
0-00-0
This fault code indicates normal operations.
Fault
code
Description
Power
lED
Fault
lED
Fault
icon
Solutions
0-00-0 None
On
Off
-
No errors