test 9 – Electronic regulator

Symptom: Air flows continuously through the torch.
1. Turn off the machine and disconnect power.
2. Disconnect the electronic regulator control cable (J6) from the power board.

• If air continues to flow, replace the electronic regulator.
• If the air stops flowing, verify the DSP board by replacing it with a known good one. If the DSP board is not the

problem, replace the power board.

Electronic

regulator J6

Pressure sensor J3

Pressure switch/auxiliary

contactor J5

Inverter temperature

sensor J2

Fan J1