Machine interface pinout, Machine interface pinout -5, Powermax – Hypertherm Powermax105 Service Manual User Manual
Page 131

Mechanized cutting
powermax
105 Service Manual
7-5
3
4
12
13
14
5
6
Machine interface pinout
Refer to the following table when connecting the Powermax105 to a torch height controller or CNC controller with a
machine interface cable.
Signal
type
Notes
Connector sockets External cable wires
Start (start plasma) Input
Normally open.
18 VDC open circuit voltage at
START terminals. Requires dry
contact closure to activate.
3, 4
Green, black
Transfer (start
machine motion)
Output Normally open. Dry contact closure
when the arc transfers.
120 VAC/1 A maximum at the
machine interface relay.
12, 14
Red, black
Ground
Ground
13
Voltage divider
Output Divided arc signal of 20:1, 21.1:1,
30:1, 40:1, 50:1 (provides a
maximum of 15 V).
5 (-), 6 (+)
Black (-), white (+)