Torch componenT replacemenT
10-18
powermax
105 Service Manual
Replace the positioning sleeve
Refer to the appropriate figure(s) on the previous page and complete the following instructions.
1. Slide the coupler off the end of the torch lead.
2. Slide the positioning sleeve (Duramax 180° full-length machine torch) off the end of the torch lead.
3. Slide the gear rack out of the groove in the positioning sleeve.
4. Slide the gear rack into the groove in the new positioning sleeve.
5. Slide the new positioning sleeve (Duramax 180° full-length machine torch) over the end of the torch lead.
6. Slide the coupler over the end of the torch lead.
Replace the torch lead
Refer to the appropriate figure(s) on the previous page and complete the following instructions.
1. Slide the coupler off the end of the torch lead.
2. Slide the positioning sleeve (Duramax 180° full-length machine torch) off the end of the torch lead.
3. Unscrew the strain relief body from the strain relief nut on the new torch lead.
4. Slide the positioning sleeve (Duramax 180° full-length machine torch) over the end of the new torch lead.
5. Slide the coupler over the end of the new torch lead.
Replace the gear rack
Refer to the appropriate figure(s) on the previous page and complete the following instructions.
1. Slide the gear rack out of the groove in the positioning sleeve.
2. Slide the new gear rack into the groove in the positioning sleeve.
Replace the coupler
Refer to the appropriate figure(s) on the previous page and complete the following instructions.
1. Slide the coupler off the end of the torch lead.
2. Slide the new coupler over the end of the torch lead.