Utility system menu, 10 utility system menu – Comtech EF Data SMS-7000 User Manual
Page 99

SMS-7000 Modem Protection Switch
Operation
Rev. 3
3–29
3.4.10
Utility System Menu
TIME:
HH:MM:SS AM/PM
DATE:
MMDDYY
Scroll left or right and press [
↑] or [↓] to set, then press [ENTER].
REMOTE BAUD RATE
nnnnn bit/s
parity
This is the protocol set-up between the switch and an external terminal.
The terminal may or may not be used to control the switch, or to make
configuration changes to the modems. Scroll left or right and press [
↑] or
[
↓] to set, then press [ENTER].
Rate Options: 19200, 9600, 4800, 2400, 1200, 600, 300, 150, 110.
Parity: EVEN, ODD, or NONE.
REMOTE ADDRESS
nnn
This is the address (nnn = 1 to 255) of the switch. Scroll left or right and
press [
↑] or [↓] to set, then press [ENTER].
Note: Address 0 is reserved for global communications.
REMOTE TYPE
type
Scroll left or right, then press [ENTER]. Options: EIA-485 (2- or
4-wire), or EIA-232.
MODEM CONTROL BAUD RATE
nnnnn bps
Scroll left or right, then press [ENTER]. Options: 9600 or 19.2 kbit/s.
Controls the baud rate between the switch and the modems.
LAMP TEST ??
Press [ENTER] to test.
DISPLAY CONTRAST
LEVEL: nnn
Scroll left or right and press [
↑] or [↓] to set, then press [ENTER].
nnn = 1 to 100.
Changes the darkness of the display characters.
M&C MODULE FIRMWARE
FW/nnnnnn-ddr
MM/DD/YY
Firmware # and date alternate on the display.
DATA MODULE #n FIRMWARE
FW/nnnnnn-ddr
MM/DD/YY
Firmware # and date alternate on the display.
Displays “NOT AVAILABLE” if not in system.