About switch, A.6 about switch – Comtech EF Data SMS-7000 User Manual
Page 137

SMS-7000 Modem Protection Switch
Remote Control Operation
Rev. 3 Draft
A–21
Prime
Modem
System
Stored
Faults
Command:
Response:
MM/DD/YY'cr'
COMM_xxx'cr'
MOD_CONFIG_VFY_xxx'cr'
DMD_CONFIG_VFY_xxx'cr'
ADD_xxx'cr'
MOD_CONFIG_LOAD_xxx'cr'
DMD_CONFIG_LOAD_xxx'cr'
PRIME_ASSIGNMENT_xxx'cr'
MU_COMM_xxx'cr'
(See Note)
MU_ADD_xxx'cr''lf']
(See Note)
Where: n = 1 to 8 (prime modem number).
Modem Communications (OK/FLT)
Modulator Config Verify (OK/FLT)
Demodulator Config Verify (OK/FLT)
Prime Modem Address (OK/FLT)
Modulator Config Loaded (OK/FLT)
Demodulator Config Loaded (OK/FLT)
Prime Assigned to Backup (OK/FLT)
Multiplexer Unit Communications (OK/FLT)
Multiplexer Unit Address (OK/FLT)
Note: Status only returned if multiplexer unit is attached.
Equipment
Stored
Faults
Command:
Response:
DATA_MODULE_1_xxx'cr'
DATA_MODULE_2_xxx'cr'
DATA_MODULE_3_xxx'cr'
DATA_MODULE_4_xxx'cr'
DATA_MODULE_5_xxx'cr'
DATA_MODULE_6_xxx'cr'
DATA_MODULE_7_xxx'cr'
DATA_MODULE_8_xxx'cr'
IF_MODULE_xxx'cr'
PS1_xxx'cr'
PS2_xxx'cr'
NVRAM_CLK_xxx'cr'
M&C_xxx'cr'
I2C_xxx'cr''lf']
Data Switch Module #1 (OK/FLT)
Data Switch Module #2 (OK/FLT)
Data Switch Module #3 (OK/FLT)
Data Switch Module #4 (OK/FLT)
Data Switch Module #5 (OK/FLT)
Data Switch Module #6 (OK/FLT)
Data Switch Module #7 (OK/FLT)
Data Switch Module #8 (OK/FLT)
IF Switch Module (OK/FLT)
Power Supply #1 (OK/FLT)
Power Supply #2 (OK/FLT)
NVRAM/Clock (OK/FLT)
M&C Controller (OK/FLT)
I2C Bus (OK/FLT)
A.6 About
Switch
Equipment
Type
Command:
Response:
Where:
tttttttt = Equipment type.
xxx.yyy.zzz = Software version number (0.0.0 to
999.999.999).
This command returns the equipment type and
software version of the addressed device.
M&C
Firmware
Information
Command:
Response:
VER_aaa.bbb.ccc'cr'
FW/nnnnnn-zzr,mm/dd/yy'cr''lf']
Where:
aaa.bbb.ccc = Software version number (0.0.0 to
999.999.999).
nnnnnn = Firmware number (0 to 99999).
zz = Firmware dash number (0 to 99).
r = Firmware revision (-, or A to Z).
mm = 1 to 12 (month).
dd = 1 to 31 (day).
yy = 00 to 99 (year).