beautypg.com

7 unbalanced data ports – Comtech EF Data SMS-7000 User Manual

Page 68

background image

Installation

SMS-7000 Modem Protection Switch

2–34

Rev. 3

2.6.2.7

Unbalanced Data Ports

Unbalanced data ports on 75

BNC coax connectors contain G.703, D&I, and external

clock signals. These data ports also facilitate IBS, D&I, or IDR data. When selected from
the control panel, the Unbalanced External Clock replaces the external clock signals on
J1, J3, and J6. The pinouts are shown in Table 2-15.

C AU TIO N

When using the G.703 unbalanced data ports for other than IDR data, be
certain there is no connection to the J6 (EIA-422) or J1 (V.35) ports. When
using G.703 data, all data switch modules must have jumper JP1 in
EIA-422 position (with jumpers connecting the middle pin and the pin
closest to the front of the switch module).

Table 2-15. Unbalanced Data Connectors

Signal Name

Pin #

IBS

IDR

D&I

CP1

G.703 SD

G.703 SD

DDI

CP2

G.703 RD

G.703 RD

IDO

CP3

Open

Open

DDO

CP4

Open

Open

IDI

CP5

EXC

EXC

EXC