System status switching menu, 6 system status switching menu – Comtech EF Data SMS-7000 User Manual
Page 91

SMS-7000 Modem Protection Switch
Operation
Rev. 3
3–21
3.4.6
System Status Switching Menu
MOD mmmmmmmm Byxn Bzxn
DMD dddddddd Byxn Bzxn
Status window.
Displays summary of active prime Mods and online backup Mods on
Line 1.
Displays summary of active prime Demods and online backup Demods
on Line 2.
If a prime or backup Mod/Demod is faulted, an “F” alternates with
Mod/Demod n # on display.
Where:
Mmmmmmmm = 1 through 8 active prime Mods/Demods.
– = Not active.
y = 1 backup Mod/Demod.
z = 2 backup Mod/Demod.
x = – if backup Mod/Demod is not online or HOT STANDBY.
x = -> indicates prime Mod/Demod being backed up.
x is blinking '–' indicates = transition to HOT STANDBY mode.
x is blinking '– >' indicates = Mod/Demod Backup operation in
process.
MOD mmmmmmmm
By xxxxx n Bz xxxxx n
Status window.
One location for each active prime.
(mmmmmmmm = 1 through 8.)
'–' = if inactive.
y = 1 backup Mod.
z = 2 backup Mod.
xxxxx = Condition of backup with respect to channel n: “STDBY” or
“BCKUP”.
(flashing if in process).
n = Channel # for prime modem.
DEMOD dddddddd
By xxxxx n Bz xxxxx n
Status window.
One location for each active prime.
(dddddddd =1 through 8.)
'–' = if inactive.
y = 1 backup Demod.
z = 2 backup Demod.
xxxxx = Condition of backup with respect to channel n: “STDBY” or
“BCKUP”.
(flashing if in process).
n = Channel #.