SMS-7000 Modem Protection Switch

Installation

Rev. 3

2–27

2.6.2.1

EIA-422/8 kbit/s Terrestrial Data (J6)

This data port is used for IBS-422 terrestrial data or IDR 8 kbit/s terrestrial overhead
data. The connector is a 37-pin female D, with one connector per channel (Table 2-9).

C AU TIO N

When using this port for IBS or no overhead data, be certain there is no
connection to the J1 (V.35) or J3 (G.703) ports. When using EIA-422 data,
all data switch modules must have jumper JP1 in EIA-422 position (with
jumpers connecting the middle pin and the pin closest to the front of the
switch module).

Table 2-9. EIA-422 Terrestrial Data Connectors (J6)

Signal Name

Pin #

IBS

IDR

D&I

1

SHIELD

SHIELD

2
3

RS422 TXO-A

8K TXO A

4

SD A

8K TXD A

5

ST A

8K TXC A

6

RD A

8K RXD A

C

7

RTS A

RTS A

A

8

RT A

8K RXC A

B

9

CTS A

CTS A

L

10

E

11

DM A

N/C

12

R

13

RR A

N/C

E

14

M

15

EXC A

8K RXO A

O

16

RS422 RXO A

N/C

V

17

TT A

N/C

E

18

D

19

GND

GND

20

GND

GND

21

RS422 TXO-B

8K TXO B