beautypg.com

Comtech EF Data SMS-7000 User Manual

Page 67

background image

SMS-7000 Modem Protection Switch

Installation

Rev. 3

2–33

2.6.2.6

Balanced G.703/Drop & Insert Data (J3)

Primary data for IDR and D&I as well as one of three IBS data options (balanced
G.703/D&I data connector) is facilitated by using a 15-pin female D with one connector
per channel. The pinouts are shown in Table 2-14.

C AU TIO N

When using this port for other than IDR data, be certain there is no
connection to the J6 (EIA-422) or J1 (V.35) ports. When using G.703 data,
all data switch modules must have jumper JP1 in EIA-422 position (with
jumpers connecting the middle pin and the pin closest to the front of the
switch module).

Table 2-14. Balanced G.703/Drop & Insert Data Connectors (J3)

Signal Name

Pin #

IBS

IDR

D&I

1

SD A

SD A

DDI-A

2

GND

GND

GND

3

RD A

RD A

IDO-A

4

GND

GND

GND

5

Open

Open

DDO-B

6

Open

Open

IDI-B

7

EXC_A

EXC_A

EXC_A

8

EXC_B

EXC_B

EXC_B

9

SD B

SD B

DDI-B

10

Open

Open

Open

11

RD B

RD B

IDO-B

12

Open

Open

DDO-A

13

Open

Open

IDI-A

14

Open

Open

Open

15

Open

Open

Open