beautypg.com

Prime modem, A.3.2 prime modem – Comtech EF Data SMS-7000 User Manual

Page 123

background image

SMS-7000 Modem Protection Switch

Remote Control Operation

Rev. 3 Draft

A–7

Backup
Multiplexer
Unit Address

Command:
Response:

Status:
Response:

>add/MUA_Bx_yyy'cr''lf']

>add/MUA_Bx_yyy'cr''lf']

Where:

x = 1 or 2 (backup multiplexer number).

yyy = 0 to 255 (backup multiplexer address; 0 places
backup multiplexer out of service).

A.3.2 Prime

Modem

Prime
Modem
Address

Command:
Response:

Status:
Response:

>add/ADD_x_yyy'cr''lf']

>add/ADD_n_yyy'cr''lf']

Where:

x = 1 to 8 (prime modem number).

yyy = 0 to 255 (prime modem address; 0 places prime
modem out of service).

Prime
Modulator
Active
(Enable)

Command:
Response:

Status:
Response:

>add/MA_x_yyy'cr''lf']

>add/MA_x_yyy'cr''lf']

Where:

x = 1 to 8 (prime modem modulator number).
yyy = YES or NO.

Note: Enter command in Manual mode only.

Prime
Demodulato
r Active
(Enable)

Command:
Response:

Status:
Response:

>add/DA_x_yyy'cr''lf']

>add/DA_x_yyy'cr''lf']

Where:

x = 1 to 8 (prime modem demodulator number).
yyy = YES or NO.

Note: Enter command in Manual mode only.

Prime
Modulator
Priority

Command:
Response:

Status:
Response:

>add/MP_x_y'cr''lf']

>add/MP_x_y'cr''lf']

Where:

x = 1 to 8 (prime modem modulator number).
y = 1 (HIGH), 2 (MEDIUM), or 3 (LOW).

Note: Independent switching mode.

Prime
Demodulato
r Priority

Command:
Response:

Status:
Response:

>add/DP_x_y'cr''lf']

>add/DP_x_y'cr''lf']

Where:

x = 1 to 8 (prime modem demodulator number).
y = 1 (HIGH), 2 (MEDIUM), or 3 (LOW).

Note: Independent switching mode.

Prime
Modem
Priority

Command:
Response:

Status:
Response:

>add/MP_x_y'cr''lf']

>add/MP_x_y'cr''lf']

Where:

x = 1 to 8 (prime modem number).
y = 1 (HIGH), 2 (MEDIUM), or 3 (LOW).

Note: Dependent switching mode.

Prime
Modulator
On-line
Delay

Command:
Response:

Status:
Response:

>add/MD_x_yyy.y'cr''lf']

>add/MD_x_yyy.y'cr''lf']

Where:

x = 1 to 8 (prime modem modulator number).

NONE, or MANUAL.

yyy.y = 0.5 to 127.0 seconds (in 0.5 second increments).

Notes:

1. If MANUAL is selected, enter the number of seconds for

the delay.

2. Independent switching mode.