beautypg.com

Operation, B.2 operation – Comtech EF Data SMS-7000 User Manual

Page 141

background image

SMS-7000 Modem Protection Switch

M-2000-Multiplexer Utilization

Rev. 3

B–3

Table B-1. SMS-7000/M-2000 50-Pin to 37-Pin Interface Cable Pinouts

50-Pin

Signal Name

37-Pin

1

Shield

1

37

CH2 SDA

4

38

CH2 SDB

22

39

CH2 RDA

6

40

CH2 RDB

24

21

CH3 SDA

5

22

CH3 SDB

23

23

CH3 RDA

8

24

CH3 RDB

26

4

CH4 SDA

3

5

CH4 SDB

21

6

CH4 RDA

15

7

CH4 RDB

33

B.2 Operation

On the switch M&C Configuration menu, enable multiplexers by selecting YES on the
Multiplexer submenu for each modem with a multiplexer. Enter a unique address for
each multiplexer. Load all modems and set Operation mode to Auto. Refer to Table 5-1
for fault information. Refer to the M-2000 Multiplexer Installation and Operation
Manual
for further operation information.

Note: To operate with the switch, the MUX must be configured with both transmit and
receive faults enabled (ON).