Comtech EF Data SMS-7000 User Manual
Page 135

SMS-7000 Modem Protection Switch
Remote Control Operation
Rev. 3 Draft
A–19
Bit 0 = Reserved.
Character 'ai': Prime #7 system fault status character 3.
Bit 6 = 1 always.
Bit 5 = Reserved.
Bit 4 = Reserved.
Bit 3 through Bit 0 = Binary representation (0 through 10)
of the number of Prime #7 system stored faults.
Character 'aj': Prime #8 system fault status character 1.
Bit 6 = 1 always.
Bit 5 = Prime modem communications failure fault.
Bit 4 = Prime modulator configuration verify error fault.
Bit 3 = Prime demodulator configuration verify error fault.
Bit 2 = No address for prime fault.
Bit 1 = No prime modulator configuration loaded fault.
Bit 0 = No prime demodulator configuration loaded fault.
Character 'ak': Prime #8 system fault status character 2.
Bit 6 = 1 always.
Bit 5 = Prime not assigned to backup fault.
Bit 4 = Prime multiplexer communications failure fault.
Bit 3 = No address for prime multiplexer fault.
Bit 2 = Reserved.
Bit 1 = Reserved.
Bit 0 = Reserved.
Character 'al': Prime #8 system fault status character 3.
Bit 6 = 1 always.
Bit 5 = Reserved.
Bit 4 = Reserved.
Bit 3 through Bit 0 = Binary representation (0 through 10)
of the number of Prime #8 system stored faults.
Character 'am': Equipment fault status character 1.
Bit 6 = 1 always.
Bit 5 = Data Switch Module #1 fault.
Bit 4 = Data Switch Module #2 fault.
Bit 3 = Data Switch Module #3 fault.
Bit 2 = Data Switch Module #4 fault.
Bit 1 = Data Switch Module #5 fault.
Bit 0 = Data Switch Module #6 fault.
Character 'an': Equipment fault status character 2.
Bit 6 = 1 always.
Bit 5 = Data Switch module #7 fault.
Bit 4 = Data Switch module #8 fault.
Bit 3 = IF Switch Module fault.
Bit 2 = Power Supply #1 fault.
Bit 1 = Power Supply #2 fault.
Bit 0 = NVRAM/Clock fault.
Character 'ao': Equipment fault status character 3.
Bit 6 = 1 always.
Bit 5 = M&C Controller fault.
Bit 4 = I2C fault.
Bit 3 through Bit 0 = Binary representation (0 through 10)
of the number of equipment stored faults.