Stored faults/alarms menu, 9 stored faults/alarms menu – Comtech EF Data SMS-7000 User Manual
Page 97

SMS-7000 Modem Protection Switch
Operation
Rev. 3
3–27
3.4.9
Stored Faults/Alarms Menu
TX OPERATIONAL FAULTS x
HH:MM:SS MM/DD/YY
x = Number of events (0 to 9), where 0 is oldest. Time and date
displayed if fault is recorded, otherwise displays “NO FAULT.”
Scroll up or down to see number of faults stored, up to 10.
Press [ENTER] to see fault.
RX OPERATIONAL FAULTS x
HH:MM:SS MM/DD/YY
x = Number of events (0 to 9), where 0 is oldest. Time and date
displayed if fault is recorded, otherwise displays “NO FAULT.”
Scroll up or down to see number of faults stored, up to 10.
Press [ENTER] to see fault.
SYS FAULTS
BACKUP #n
HH:MM:SS MM/DD/YY
(n = 1 through 8)
x = Number of events (0 to 9), where 0 is oldest. Time and date
displayed if fault is recorded, otherwise displays “NO FAULT.”
Scroll up or down to see number of faults stored, up to 10. Press
[ENTER] to see fault.
BK-UP MU COMM FAILURE AND NO ADDRESS FOR
BK-UP MU displayed only if multiplexer is enabled.
SYS FAULTS
PRIME #n
HH:MM:SS MM/DD/YY
(n = 1 through 8)
x = Number of events (0 to 9), where 0 is oldest. Time and date
displayed if fault is recorded, otherwise displays “NO FAULT.”
Scroll up or down to see number of faults stored, up to 10. Press
[ENTER] to see fault.
PRIME MU COMM FAILURE and NO ADDRESS FOR
PRIME MU displayed only if multiplexer is enabled.
EQUIPMENT FAULTS
x = Number of events (0 to 9), where 0 is oldest. Time and date
displayed if fault is recorded, otherwise displays “NO FAULT.”
Scroll up or down to see number of faults stored, up to 10. Press
[ENTER] to see fault.
CLEAR ??
STORED FAULTS
YES or NO.
Press [ENTER] twice to clear stored faults.