beautypg.com

Configuration backup 1 and 2 menu, 1 configuration backup 1 and 2 menu – Comtech EF Data SMS-7000 User Manual

Page 79

background image

SMS-7000 Modem Protection Switch

Operation

Rev. 3

3–9

3.4.1

Configuration Backup 1 and 2 Menu

Refer to Figure 3-3.

BACKUP MODEM #n
ADDRESS

Set # other than 0. Numbers 9 or 10 are recommended when the
protection system is full; two backups and eight prime modems.
Address: 0 to 255.

Note: Address 0 is reserved as a global address.

Upon entry, the current status is displayed. Press [

↑] or [ ↓] to

make the selection. Press [ENTER] to execute the change.

BACKUP MOD #n

Turn On or Off the switch to recognize that the Backup modulator
status.

Upon entry, the current status is displayed. Press [

↑] or [ ↓] to

make the selection. Press [ENTER] to execute the change.

BACKUP DEMOD #n

Turn On or Off the switch to recognize that the Backup
demodulator status.

Upon entry, the current status is displayed. Press [

↑] or [ ↓] to

make the selection. Press [ENTER] to execute the change.

BACKUP #n SWITCHING
MODE

When a failure occurs, DEPENDENT mode switching will place
the whole Prime modem to the Backup modem. When a failure
occurs, INDEPENDENT switching will only switch half the
modem; either the Modulator or the Demodulator.

Upon entry, the current status is displayed. Press [

↑] or [ ↓] to

make the selection. Press [ENTER] to execute the change.

BACKUP #n PRIME
MODEMS

Place the Prime modem numbers in the spaces provided so that the
Backup modem will only look to backup the identified prime
modems.
e.g., 1 _ 3 _ 5 _ _ _. This example displays the Backup modem
replacing modem #s 1, 3, and 5.

Upon entry, the current status is displayed. Press [

↑] or [ ↓] to

make the selection. Press [ENTER] to execute the change.

BACKUP #n
MULTIPLEXER

Used when the Comtech EFData M-2000 multiplexer is included in
the modem set-up.

Upon entry, the current status is displayed. Press [

↑] or [ ↓] to

make the selection. Press [ENTER] to execute the change.

BACKUP #n
MULTIPLEXER
ADDRESS

Display status of multiplexer: ‘YES or NO’.

Upon entry, the current status is displayed. Press [

↑] or [ ↓] to

make the selection. Press [ENTER] to execute the change.