beautypg.com

Faults, Revision status, 4 operation mode – Comtech EF Data SMS-7000 User Manual

Page 102: 6 faults, 7 revision status

background image

Operation

SMS-7000 Modem Protection Switch

3–32

Rev. 3

3.5.2.4 Operation

Mode

Two modes of operation are available for the switch.

Auto — Automatically allows the Backup modem to replace any prime modem
when a MOD or DEMOD failure occurs.

Manual — When Manual mode is selected, the system provides a dedicated
menu through which the user may assign backup RX and TX functions to replace
the prime modems.

Enter 0 under the CONFIG/OPERATION MODE/MANUAL/MODEM BACKUP
PRIME MODEM

menu to place the backup service on the intended prime modem.

3.6 Faults

Alerts to modem or switch faults are provided in several ways:

Indicators on the switch control panel with specific information available in the
Fault/Alarm menu.

On demand via the switch remote port. Specifics for both switch and modem
faults are available.

Audio and/or visual indicators wired directly to the Switch Fault and Modem
Status ports on the rear of the SCU.

Refer to Chapter 5 for troubleshooting switch faults and modem faults.

3.7 Revision

Status

Refer to Table 3-3 for revision software history.

Table 3-3. Revision Status

Revision

FW/4958-1

Description

1.1.1

Original Issue

1.1.2

A

User interface changes

2.1.1

B

Added M2000 Multiplexer and revision emulation functionality.

2.1.2

C

User interface changes.

2.1.3

D

User interface changes.

2.1.4

E

Corrected communication faults on modem, data, and IF module.

2.1.5

F

Corrected automatic mode problem.

2.1.6

G

Corrected backup of SLM8650 and SLM6650 for 6650-00,
6650-02, 8650-00, 8650-02, 3650-00, 3650-02 modem types.

2.1.7

H

Corrected online signal problem.

2.1.8

J

Allow switch to operate with SDM8000 modem.