Controls, LEDs and Connectors

iVPX7225 Installation and Use (6806800S11C)

47

7

ETH_TDO

P2XMC 12D 4 P

P2XMC 12D 4 N PLD_TDO

P2XMC 12D 3 P

P2XMC 12D 3 N

8

ETH_TMS

GND

GND

PLD_TMS

GND

GND

9

ETH_TCK

P2XMC 12D 6 P

P2XMC 12D 6 N PLD_TCK

P2XMC 12D 5 P

P2XMC 12D 5 N

10

ETH_TRST_L

GND

GND CPU_TDI

GND

GND

11

SPI_MOSI

NC (X8D OPT)

NC (X8D OPT)

CPI_TDO

SATA_XMC_TX-

SATA_XMC_TX+

12

SPI_MISO

GND

GND

CPU_TMS

GND

GND

13

SPI0_CS_L

NC (X8D OPT)

NC (X8D OPT)

CPU_TCK

NC (X8D OPT)

NC (X8D OPT)

14

SPI1_CS_L

GND

GND

CPU_TRST_L

GND

GND

15

SPI_CLK

P2XMC 12D 8 P

P2XMC 12D 8 N PCH_TDI

P2XMC 12D 7 P

P2XMC 12D 7 N

16

SPI_HDR_HOL
D0_L

GND

GND

PCH_TDO

GND

GND

17

SPI_HDR_HOL
D1_L

P2XMC 12D 10 P P2XMC 12D 10

N

PCH_TMS

P2XMC 12D 9 P

P2XMC 12D 9 N

18

SPI_HDR_PWR

GND

GND

PCH_TCK

GND

GND

19

CORE_PGOOD

P2XMC 12D 12 P P2XMC 12D 12

N

+VTT

P2XMC 12D 11
P

P2XMC 12D 11 N

Rows F and C of XJ16 are intended for use with a factory test XMC. These signals may conflict
with certain XMC's Rear/User IO signals.

A special iVPX7225 factory build option routes 8 additional XMC Differential I/O signals to
P2 in lieu of Mini-DP and SATA P2. Refer to the VITA 46.9 X8d Pattern.

Table 3-8 XJ16 Connector Pinout (continued)


Pin

Row F

Row E

Row D

Row C

Row B

Row A