Table 2-1, Environmental requirements, Hardware preparation and installation – Artesyn iVPX7225 Installation and Use (April 2015) User Manual
Page 41

Hardware Preparation and Installation
iVPX7225 Installation and Use (6806800S11C)
22
Product Damage
High humidity and condensation on the board surface causes short circuits.
Do not operate the board outside the specified environmental limits. Make sure the
board is completely dry and there is no moisture on any surface before applying power.
Table 2-1 Environmental Requirements
Environmental Parameter
Air Cooled
Conduction Cooled
Cooling Method
Forced Air
Conduction
Operating Temperature
-40 °C to +71 °C
1
-40 °C to +71 °C
2
(card edge)
Storage Temperature
-50 °C to +100 °C
-50 °C to +100 °C
Vibration Sine (10 min/Axis)
5G, 15 to 2000 HZ
10G, 15 to 2000 HZ
Vibration Random (1 Hr/Axis)
0.04g2/Hz, 15 to 2000 Hz
(8GRMS)
3
0.1g2/Hz, 15 to 2000 Hz
(12GRMS)
4
Shock
30g/11ms
40g/11ms
Humidity
to 95% RH non-condensing
to 95% RH non-condensing
1. Ambient temperature at sea-level without PMC/XMCs installed, while maintaining >= 80% CPU
performance (<=20% frequency down-step or duty-cycle throttling).
2. Measured at card edge, without PMC/XMCs installed, while maintaining >=80% CPU performance
(<=20% frequency down-step or duty-cycle throttling).
3. Flat 15-1000Hz, -6db/octave 1000Hz – 2000Hz [MIL-STD 810F Figure 514.5C-17]
4. +3db/octave 15-300Hz, Flat .1g2 300-1000Hz, -6db/octave 1000Hz – 2000Hz [MIL-STD 810F
Figure 514.5C-8]