Model” drop down box illustrated above. You may only assign a model

from the combo box when the display has been set as FULLSIZE in ‘Startup

Setting’. Please ensure the right model is assigned to prevent an improper

monitoring state.

Spin Speed

Adjust the spin speed of the image around the display. Select “Fixed” to

disable image spin. Move the slider to the right to speed up the spin speed,

and to the left to slow spin speed.

[*Note]: The action may cause Monitor System Schedule to pause, unless

released or AP3 restarted.

Display Adjust

Forward – To adjust screen position to the left when spin speed is “Fixed.”

Reverse – To adjust screen position to the right when spin speed is “Fixed.”

Save – To save screen offset position. Some DynaScan displays will save it

automatically, please wait for 30 seconds to save the new settings after

offsetting the position.

Power Control Enable

Automatic shutdown operation of the computer will cause display shutdown,

and computer startup will start up AP3 and display. If the setting is not

selected, above function will be disabled. Default is set as (enable).

Power On / Off

Power On – Start up display.

Power Off – Shut down display.

[*Note]: When Excool is disabled, click Power Off once to turn off the motor

(LED modules remain on). The LED modules will automatically turn off

when motor comes to a stop. Clicking Power Off a second time, with motor

off but rotating, will cause the LED modules to turn off.

[*Note]: When Excool is enabled, click Power Off once to start Excool

function with LED modules off. Click Power Off a second time to skip

Excool function and turn off the motor first with LED modules on. The LED

modules will automatically be turned off when motor comes to a stop. Click

Power Off a third time, to turn LED modules off.

[*Note]: The action may cause Monitor System Schedule to pause, unless

released or AP3 restarted.