Count: It sets the device number for every update. The default is to
update one device a time.
Time: It sets the time interval for every update. The unit is
millisecond and the default is 1000 millisecond (= 1 second.)
Stop Transfer: When selected the Server will stop the file transmission in
between all Clients. The affected item is only limited to the transfer
between the Server and Client. The transfer between Client and Client
is not affected. The default is disabled.
Hide Final: It hides the transferred files from the list in the Monitor menu.
Net Setting
Click Net Setting to show the following settings.
Local IP: It sets the IP address used by the local device. The default
is 127.0.0.1.
Local Port: It sets the port used by the local device. The default is
8765.
Use Virtual Server: It sets enable/disables the virtual server. The
default is enabled.
Virtual Server IP: It sets the IP address used by the virtual server.
Virtual Server Port: It sets the port used by the virtual server.
Network Speed
Download: It sets the maximum bandwidth for downloading. The unit is
in KBits.
Upload: It sets the maximum bandwidth used for uploading. The unit is
in KBits.
Publish Port: It sets the port used for publishing. The default is 8767.