DynaScan Indoor 360 Degree LED Video Display DS0808 User Manual
Page 10
Copyright © 2008 DynaScan Technology Corp. 10
Label 2 –Operational function section of played contents provides function
buttons like
‘Play’,
‘Pause’,
‘Stop’,
‘backward’,
‘forward’,
‘jump to beginning’, and
‘jump to end’. The section also provides the track bar
of file progression, and a Current Time Indicator (CTI) that will move along the
timeline. Clicking and dragging the CTI will change play progress accordingly. To
the right of buttons is relevant information column of files. The left time displays the
current played time and the right number represents total length of file. This is
followed by a display of the file name and current playing status. The last drop
down box lists all currently played files for users to select objects of operational
function section, as AP3 is capable of simultaneously playing different files in sub-
pictures with different sizes by dividing several ‘displays’ or one ‘display’.
Label 3 – operational area of each function. Please refer to detailed introduction
of functions for illustration of each item in operational area.
Label 4 – Feedback of status of the DynaScan equipment. This includes
temperature sensor, power status, motor status, thermal alarm, tilt alarm, preheat,
precool and excool.
• Temperature sensor will detect the temperature (centigrade) in the
machine body, displaying a green number
to represent normal
temperature and a red number
when the temperature exceeds
safety settings.
• Power status displays (grey) when power is off; (green) when
power is on, and unexpected power status
(yellow). (for certain
display Models)
• Motor status displays (grey) when motor is off, (green) when
motor is on, and
(red) when motor is abnormal. If an abnormal
condition be detected, the display will be shut down automatically.
• Thermal alarm will show (red) when detecting over-temperature. If
it is higher than the safety setting, the LED display modules will be
turned off with the motor continuously running to cool machine. Once
the temperature returns to a normal level, the LED display modules
will turn on again.
• Tilt alarm will show (red) and turn off the display when a tilt of the
machine body over 15 degrees is detected.
• If the drum temperature is below 5
°C
when the DynaScan display
starts, it will enter into a “Preheat” mode, showing
(yellow) and
motor turned off. It will then turn into normal mode after the drum
temperature is above 5
°C
or after 8 minutes. (Only for certain display