Remote Publish (Server Only).

Click the ‘Remote Publish’ button to show the Machine Select browser,

which lists the target name, IP and ports of remote devices that have been

set up in AP3 Config (see page 123 for more information about setting up

remote devices). Select which targets you want to publish to; you may

select individual machines by using the individual checkboxes, or use

‘Select All’ for all devices and ‘Clear Select’ to uncheck all devices.

Publish can be set to specified View. Input the name of the View in

“Frame Name” by dragging “Frame” from “Type”, e.g. default Views as

Default, Region1, and Region2 etc. This Publish will play in the specified

View, and not affect the playing in other Views.

When the playing client is displaying multiple screens, the user can

specify which screen to deliver the content to using the Screen ID.

You may preset the date and time to begin playing the published content.

The View will not play the new content until the preset playing time. If a

future play time has not been specified, content will play immediately after

remote publish has finished transferring.

Click OK to begin transmitting.

Note: Applies to AP3 Server only.

Appoint only view with sound

If a view has not been assigned as the single audio source of a layout, all

views may play audio simultaneously. To avoid this, select the view and

click “Set Sound” button to set as the only audio source and mute all other

views.

Two sources with the same Capture devices cannot be played simultaneously