Copyright © 2008 DynaScan Technology Corp. 11
models)
• If the drum temperature is above 35
°C
when the DynaScan display
starts, it will turn into “Precool” mode with showing
(blue), with
motor running and the LED display modules off. It will turn into normal
mode after the drum temperature is below 35
°C
or after 5 minutes
(Only for certain display models).
• When shutting down DynaScan display (power is on), it will turn into
“Excool” mode with showing
(blue), with the motor running and
LED modules off for approximately 6 minutes. It will then automatically
power off the display automatically and the icon will disappear. (Only
for certain display models)