Traffic Generator

94

ETS-1000G

MAC/IP and VLAN flood

MAC/IP and VLAN flood

MAC, IP and VLAN flood modes allow to consume the limited addressable
memory of the DUT and to check if it has any protection against this kind of
attacks.

Note: Flood traffic is not included in the basic configuration. It is available as an

option upon special request.

To perform the test you need to:
1.
Connect 10G/1G port of the ETS-1000G to the NUT/DUT.

2. Open the Network Setup menu on the local and remote devices,

specify the IP address of test port or make sure that the device has
received the correct IP address via DHCP.

3. Open the Traffic generator menu on the local device:

Set the generation parameters.

Set the header parameters according to the information provided
in Main header parameters on page 26 and Additional header
parameters
on page 27 section.

Select On (

) in the Send field. Test traffic generation will begin

from the 10G/1G port to NUT/DUT. Each packet will contain
random source MAC/IP address or VLAN Priority/ID value.